Temperature sensor outdoor, RS-485
(upravuje se pomocí modulu Ujištění zákazníka)
(upravuje se pomocí modulu Ujištění zákazníka)
(upravuje se pomocí modulu Ujištění zákazníka)
This version uses for the converter a box with same mechanical dimensions as "Box" version. Temperature sensor Pt100 is not in the version "Cable" on the box, but it is placed outside the box, on a 2 meters cable. Only one bushing for a cable is assembled from the box.
The cable with powering and RS-485 line and the sensor are connected through one cable bushing. The sensor is connected on 2 meters cable Pt30 and it is included.
Basic parameters | |
+ Cover level | case IP68 / distribution frame: IP10 |
+ Converter operating temperatures | -25...+ 80°C |
+ Input signal range | range –55 .. 640 °C |
+ Supported sensors | Pt100 and Pt1000 dle IEC 751 |
+ Connection of input sensor | 3 or 2 wire |
- influence of leads resistance | < ± 0,1°C |
+ Measuring error | 0,03% from range |
Communication | |
+ Communication parameters | 9600 8N1 |
+ Communication line | RS-485 without termination |
+ Period of temperature measuring | 1x / 810 ms |
Other | |
+ Supply voltage | 8V to 28V DC, protection against reversing of polarity |
+ Current taking | - taking during measuring typ. 2 mA - taking during emission to RS-485 typ. 60 mA |
+ Leaders connection | distribution clames CUU 2,5 mm2 |
Type tests | |
- Basic type test according to | ČSN EN 770 |
- EMC according to | ČSN EN 61326-1 |
- Safety according to | ČSN EN 61010-1 |
Data sheet